√ Long-distance detection: methane and methane-containing gas leakage detection at a distance of 200 meters
√ Anti-cross-interference: Specific laser detection, only reacts to methane gas and is not affected by environmental conditions
√ Convenient application: automatic detection at startup, no need for periodic calibration and maintenance-free
Performance| parameter | minimum value | Typical value | maximum value | unit | |
|---|---|---|---|---|---|
| General parameters | |||||
| Storage temperature | -40 | - | 70 | ℃ | |
| operating temperature | -10 | - | 50 | ℃ | |
| Working humidity | - | - | 98 | % | |
| work pressure | - | 101 | - | kPa | |
| Concentration measuring range | 0.00 | - | 100000 | ppm·m | |
| Effective gas measurement distance | 0.5 | - | 200 | m | |
| measurement accuracy | ±10%@10000ppm·m (75% reflectivity & slow-speed stable measurement) | ||||
| Sensitivity | 5@≤50m/10@≤100m/100@≤200m | ppm·m | |||
| Communication Interface | |||||
| 485 interface | baud rate | - | 9600 | - | baud |
| Electrical properties | |||||
| Operating Voltage | 12 | - | twenty four | V | |
| Working current | - | 200 | - | mA | |
| Optical parameters | |||||
| detection light | Near infrared (1653nm) laser safety level ClassⅠ | ||||
| Indicating light | Green light (532nm) laser safety level ClassⅢR | ||||
| Dimensions and weight | |||||
| Diameter*Length | 75*130 | mm | |||
| weight | 450 | g | |||
Overall dimensions (unit: mm)

Notice:
1.When using, avoid excessive irradiation angle, which will affect the response speed and accuracy of the measurement results.
2.The laser beam emitted by the product must pass through the target gas, otherwise the target gas concentration will not be measured.









评价